UV Ballast family - UV lamp drivers for operating two UVC lamps with 4 pin connector
-
Lamp power: 30...180W
-
Lamp current: up to 2,1 A
-
Dimensions: 248 x 105 x 59 mm (9.76 x 4.13 x 2.32 inch)
-
No. of Lamps: 2
-
preheat start for more frequent switching
Features
- preheat start ballasts for optimal lamp operation
- double device - powers two lamps, independent lamp operation even if one lamp is defective or disconnected
- lamp and ballast status indication - green and red LEDs - potential free relay contacts
- standard operation - easy system start-up "plug and play" - no DIP-switch / no RS485 interface - no adjustable operation parameters - no remote operation control
- metall housing, designed for optimal thermal flow
- push-in contacts for quick installation
- high efficiency
- active power factor correction (PFC) low THD according to EN 61000
Technical Specification
supply voltage: | 230V AC ± 10% /45-65Hz (115V AC types on request) |
---|---|
efficiency: | >90% |
operation temperature: | max. 50°C (122°F) at TC-point |
ambient temperature: | 0 - 40°C (32 - 104°F) |
IP code: | IP20 |
dimensions (LxWxD): | 248 x 105 x 59 mm (9.76 x 4.13 x 2.32 inch) |
UV lamp types
- GHO64T5-1
- GIA120
- GIA200
- GIA843T5LCA
- GIA1554T5LCA
- GIA843T6LCA
- GPHA357T5L
- GPHA357T6L
- GPHA843T5L
- GPHA843T6L
- GPHA1000T5L
- GPHA1000T6L
- GPHA1554T5L*
- GPHHA357T6L
- GPHHA843T6L
- GPHHA1000T6L*
- LTC115T12
- NNI 60/35 XL
- NNI 80/36 U
- NNI 120/84
- NNI 125/84 XL
- NIL 125/84 XL
- NIQ 120/84
- NIQ 125/84 XL
- NNI 200/107
- NNI 201/107 XL
- NIQ 200/107
- NIQ 201/107 XL
- TUV 115W (R) VHO (T12)
- TUV 64T5 HO
- TUV 130W XPT
- TUV 180W XPT
- UNI120
- UNI200
* forced ballast cooling required